SparkleFlow is the acclaimed packaging solution that combines all aspects of a software packaging project into a single interface. Preparing an application migration? Need to reduce your TCO? Need to manage lots of applications? Want to setup your applications right now and not waste to much of your value time? SparkleFlow Package Management offers the complete solution for creating structure in your packaging project.
SYMPTOMS:
(KB930876) When you use SoftGrid Client Management to try to update a Desktop Configuration
Server, you receive the following error message:
The SoftGrid Client failed to download MIME information from ServerName.
The SoftGrid Client detected a socket-related error. Please try again in a few minutes. If
the problem persists, please report the following error code to your System Administrator.
Error code: xxxxxx-xxxxxx0A-80038003
CAUSE:
This problem may occur when the port is not valid. Or, this problem may occur because the
SoftGrid Client cannot communicate with the port.
RESOLUTION:
To resolve this problem, make sure that you specify a valid port on the Servers tab of the
SoftGrid Client. Also, make sure that the SoftGrid Client can communicate with the port. You
can use a Telnet client to test the port.
If the value in the Type box is SoftGrid Virtual Application Server, make sure that the SoftGrid
Virtual Application Server service is started. If the value in the Type box is Standard HTTP Server,
make sure that the Web server is listening. If the value in the Type box is Standard UDDI Server,
make sure that the UDDI server is listening on the correct port.